期刊文献+
共找到2,723篇文章
< 1 2 137 >
每页显示 20 50 100
Seismic Data Reconstruction and Noise Suppression Based on an Improved Weighted Fast Projection onto Convex Sets Algorithm 认领 引用
1
作者 Cheng Gao-peng Zhang Hua +3 位作者 Li Hong-xing Song Yu Yue Ming Zhang Kai-dong 《Applied Geophysics》 SCIE CSCD 2026年第1期336-351,433,434,共16页
In eld seismic data acquisition,seismic traces are often aected by substantial data gaps and strong noise interference due to environmental and instrumental factors,thus degrading the resolution and signalto-noise rat... In eld seismic data acquisition,seismic traces are often aected by substantial data gaps and strong noise interference due to environmental and instrumental factors,thus degrading the resolution and signalto-noise ratio(SNR)of the seismic profiles.Effective seismic data reconstruction and noise suppression techniques are therefore essential to recover missing signals and improve data quality.In this study,a fast projection onto convex sets(FPOCS)algorithm is proposed by incorporating an inertial parameter that involves a linear combination of the two preceding iterations based on the traditional projection onto convex sets(POCS)algorithm.Then,a weighting factor is introduced to achieve simultaneous data reconstruction and noise suppression using the weighted fast projection onto convex sets(WFPOCS)algorithm.To further suppress residual random noise in the updated solution,an optimization strategy is adopted by swapping the order of the iterative hard thresholding operator and the projection operator.The nal algorithm,termed the improved weighted fast projection onto convex sets(IWFPOCS),achieves high-efciency reconstruction and effective noise suppression.Compared with WFPOCS,the proposed method maintains fast reconstruction speed while demonstrating superior denoising performance on irregularly missing and noisy datasets.Field data experiments conrm that the proposed method signicantly improves the SNR and resolution of seismic data,oering strong practical potential for subsequent processing and interpretation. 展开更多
关键词 Seismic data reconstruction Fast projection onto convex set algorithm Curvelet transform Weighted fast projection onto convex set algorithm Noise suppression
暂未订购 下载PDF
Research on a two-step retracking algorithm for reconstructed waveforms of nearshore radar altimeters 认领 引用
2
作者 Yongjun Jia Xingwei Jiang +1 位作者 Dan Qin Bo Yuan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2026年第3期216-231,共16页
To enhance the accuracy of nearshore data products obtained from nadir radar altimeters,we introduce a novel two-step retracking algorithm for reconstructed waveforms.This approach utilizes Empirical Mode Decompositio... To enhance the accuracy of nearshore data products obtained from nadir radar altimeters,we introduce a novel two-step retracking algorithm for reconstructed waveforms.This approach utilizes Empirical Mode Decomposition(EMD)to extract trend information from the trailing edge of the waveform.Reconstructed waveforms are formed by linking the leading and trailing edge trend information.The retracking process consists of two steps:the first step focuses on retracking a segment of the leading edge to obtain 4 crucial a priori parameters.In the second step,retracking incorporates both the leading and trailing edges using the previously acquired a priori information.We tested the algorithm using data from the HY-2B radar altimeter.Results indicate that the proposed two-step retracking algorithm outperforms the Maximum Likelihood Estimation(MLE4)algorithm currently used in the operational processing of the HY-2B radar altimeter,as well as the Adaptive Leading Edge Subwaveform(ALES)algorithm,in terms of significant wave height(SWH)and sea level anomalies(SLA).Specifically,the standard deviation of the difference in SWH is reduced by 14%,and the standard deviation of the difference in SLA is reduced by approximately 18%.The two-step retracking algorithm effectively leverages trailing edge information,reduces the influence of peak noise on the leading edge,and improves both the utilization and accuracy of the waveform retracking. 展开更多
关键词 reconstructed waveforms two-step retracking algorithm radar altimeter HY-2B satellite
暂未订购 下载PDF
Image Quality Optimization in 60 kVp Head-Neck CTA:A Comparative Study of FBP,ClearView,and ClearInfinity Reconstruction Algorithms 认领 引用
3
作者 Shao-fang Wang Zhen Li +6 位作者 Li-hui Dai Huan Liu Yan-qiu Zhang Yan Huang Xiang-yue Zha Jing Zhang Qiu-xia Wang 《Current Medical Science》 SCIE CAS CSCD 2025年第6期1504-1512,共9页
Objective To compare the impact of different reconstruction algorithms on the image quality of 60 kVp head and neck CT angiography(CTA)using subjective and objective metrics,with a focus on vessel edge sharpness.Metho... Objective To compare the impact of different reconstruction algorithms on the image quality of 60 kVp head and neck CT angiography(CTA)using subjective and objective metrics,with a focus on vessel edge sharpness.Methods This prospective study enrolled 45 patients who underwent ultra-low-voltage(60 kVp)head and neck CTA.Image datasets were reconstructed with filtered back-projection(FBP),ClearView(CV)and ClearInfinity(CI)algorithms at low(30%),medium(50%),and high(70%)strengths.Image quality was assessed subjectively and objectively via the Kruskal‒Wallis test for multiple comparisons.Objective parameters,including edge rise slope(ERS)and edge rise distance(ERD),were analyzed via the Friedman test of multiple comparisons statistics.Results Subjective assessments favored the CI50 reconstruction algorithm,demonstrating superior or satisfactory results compared to the other algorithms,with significantly better vessel delineation,edge definition and diagnostic confidence(all P0.05)across all evaluated head and neck vascular segments when compared with the FBP algorithm.Conclusions The CI50 reconstruction algorithm optimizes image quality in 60 kVp head and neck CTA.It provides vessel edge sharpness comparable to FBP while offering superior vessel delineation,edge definition,and diagnostic confidence compared to FBP and CV algorithm.These findings suggest that CI50 has the potential to improve diagnostic accuracy in low-dose vascular imaging. 展开更多
关键词 Computed tomography angiography Reconstruction algorithm Deep learning reconstruction Low-dose CT Image quality Vessel sharpness 60 kVp Heal-neck imaging
暂未订购 下载PDF
Non-Neural 3D Nasal Reconstruction:A Sparse Landmark Algorithmic Approach for Medical Applications 认领 引用 被引量:1
4
作者 Nguyen Khac Toan Ho Nguyen Anh Tuan Nguyen Truong Thinh 《Computer Modeling in Engineering & Sciences》 SCIE EI 2025年第5期1273-1295,共23页
This paper presents a novel method for reconstructing a highly accurate 3D nose model of the human from 2D images and pre-marked landmarks based on algorithmic methods.The study focuses on the reconstruction of a 3D n... This paper presents a novel method for reconstructing a highly accurate 3D nose model of the human from 2D images and pre-marked landmarks based on algorithmic methods.The study focuses on the reconstruction of a 3D nose model tailored for applications in healthcare and cosmetic surgery.The approach leverages advanced image processing techniques,3D Morphable Models(3DMM),and deformation techniques to overcome the limita-tions of deep learning models,particularly addressing the interpretability issues commonly encountered in medical applications.The proposed method estimates the 3D coordinates of landmark points using a 3D structure estimation algorithm.Sub-landmarks are extracted through image processing techniques and interpolation.The initial surface is generated using a 3DMM,though its accuracy remains limited.To enhance precision,deformation techniques are applied,utilizing the coordinates of 76 identified landmarks and sub-landmarks.The resulting 3D nose model is constructed based on algorithmic methods and pre-marked landmarks.Evaluation of the 3D model is conducted by comparing landmark distances and shape similarity with expert-determined ground truth on 30 Vietnamese volunteers aged 18 to 47,all of whom were either preparing for or required nasal surgery.Experimental results demonstrate a strong agreement between the reconstructed 3D model and the ground truth.The method achieved a mean landmark distance error of 0.631 mm and a shape error of 1.738 mm,demonstrating its potential for medical applications. 展开更多
关键词 Nose reconstruction 3D reconstruction medical applications algorithmic reconstruction enhanced 3D model
暂未订购 下载PDF
Development and validation of a decision algorithm for eyelid reconstruction following oncological resection 认领 引用
5
作者 Giovanni Miotti Davide Quaglia +7 位作者 Federico Cesare Novati Pier Camillo Parodi Martina Grando Carlo Salati Leopoldo Spadea Caterina Gagliano Mutali Musa Marco Zeppieri 《World Journal of Transplantation》 2025年第2期309-319,共11页
BACKGROUND Eyelid reconstruction is an intricate process,addressing both aesthetic and functional aspects post-trauma or oncological surgery.Aesthetic concerns and oncological radicality guide personalized approaches.... BACKGROUND Eyelid reconstruction is an intricate process,addressing both aesthetic and functional aspects post-trauma or oncological surgery.Aesthetic concerns and oncological radicality guide personalized approaches.The complex anatomy,involving anterior and posterior lamellae,requires tailored reconstruction for optimal functionality.AIM To formulate an eyelid reconstruction algorithm through an extensive literature review and to validate it by juxtaposing surgical outcomes from Cattinara Hos-in dry eye and tears,which may lead to long-term consequences such as chronic conjunctivitis,discomfort,or photo-phobia.To prevent this issue,scars should be oriented vertically or perpendicularly to the free eyelid margin when the size of the tumor allows.In employing a malar flap to repair a lower eyelid defect,the malar incision must ascend diagonally;this facilitates enhanced flap advancement and mitigates ectropion by restricting vertical traction.Conse-quently,it is imperative to maintain that the generated tension remains consistently horizontal and never vertical[9].Lagophthalmos is a disorder characterized by the inability to completely close the eyelids,leading to corneal exposure and an increased risk of keratitis or ulceration;it may arise following upper eyelid surgery.To avert this issue,it is essential to preserve a minimum of 1 cm of skin between the superior edge of the excision and the inferior boundary of the eyebrow.Epiphora may occur in cancers involving the lacrimal puncta,requiring their removal.As previously stated,when employing a glabellar flap to rectify medial canthal abnormalities,it is essential to prevent a trapdoor effect or thickening of the flap relative to the eyelid skin to which it is affixed.Constraints about our proposed algorithm enco-mpass limited sample sizes and possible publication biases in existing studies.Subsequent investigations ought to examine long-term results to further refine the algorithm.Future research should evaluate the algorithm across varied populations and examine the impact of novel graft materials on enhancing reconstructive outcomes.CONCLUSION Eyelid reconstruction remains one of the most intriguing challenges for a plastic surgeon today.The most fascinating aspect of this discipline is the need to restore the functionality of such an essential structure while maintaining its aesthetics.In our opinion,creating decision-making algorithms can facilitate reaching this goal by allowing for the individualization of the reconstructive path while minimizing the incidence of complications.The fact that we have decreased the incidence of severe complications is a sign that the work is moving in the right direction.The fact that there has been no need for reintervention,neither for reconstructive issues nor for inadequate oncological radicality,overall signifies greater patient satisfaction as they do not have to undergo the stress of new surgeries.Even the minor complic-ations recorded are in line with those reported in the literature,and,even more importantly for patients,they are of limited duration.In our experience,after a year of application,we can say that the objective has been achieved,but much more can still be done.Behind every work,a scientific basis must be continually renewed and refreshed to maintain high-quality standards.Therefore,searching for possible alternative solutions to be included in one’s surgical armamentarium is fundamental to providing the patient with a fully personalized option. 展开更多
关键词 Cartilage grafts Decision algorithm Eyelid lamella grafts Eyelid reconstruction Flap transplantation Graft transplantation Mucosa grafts
暂未订购 下载PDF
Variable Reconstruction for Evolutionary Expensive Large-Scale Multiobjective Optimization and Its Application on Aerodynamic Design 认领 引用 被引量:1
6
作者 Jianqing Lin Cheng He +1 位作者 Ye Tian Linqiang Pan 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2025年第4期719-733,共15页
Expensive multiobjective optimization problems(EMOPs)are complex optimization problems exacted from realworld applications,where each objective function evaluation(FE)involves expensive computations or physical experi... Expensive multiobjective optimization problems(EMOPs)are complex optimization problems exacted from realworld applications,where each objective function evaluation(FE)involves expensive computations or physical experiments.Many surrogate-assisted evolutionary algorithms(SAEAs)have been designed to solve EMOPs.Nevertheless,EMOPs with large-scale decision variables remain challenging for existing SAEAs,leading to difficulties in maintaining convergence and diversity.To address this deficiency,we proposed a variable reconstructionbased SAEA(VREA)to balance convergence enhancement and diversity maintenance.Generally,a cluster-based variable reconstruction strategy reconstructs the original large-scale decision variables into low-dimensional weight variables.Thus,the population can be rapidly pushed towards the Pareto set(PS)by optimizing low-dimensional weight variables with the assistance of surrogate models.Population diversity is improved due to the cluster-based variable reconstruction strategy.An adaptive search step size strategy is proposed to balance exploration and exploitation further.Experimental comparisons with four state-of-the-art SAEAs are conducted on benchmark EMOPs with up to 1000 decision variables and an aerodynamic design task.Experimental results demonstrate that VREA obtains well-converged and diverse solutions with limited real FEs. 展开更多
关键词 Aerodynamic design large-scale optimization multiobjective evolutionary algorithm surrogate model variable reconstruction
暂未订购 下载PDF
An algorithm for computed tomography image reconstruction from limited-view projections 认领 引用 被引量:20
7
作者 王林元 李磊 +3 位作者 闫镔 江成顺 王浩宇 包尚联 《Chinese Physics B》 SCIE EI CAS 2010年第8期642-647,共6页
With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d... With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed. 展开更多
关键词 limited-view problem computed tomography image reconstruction algorithms reconstruction-reference difference algorithm adaptive steepest descent-projection onto convex sets algorithm
暂未订购 下载PDF
Structural damage detection based on model reduction and response reconstruction 认领 引用
8
作者 ZOU Yun-feng SU Yun-hui +2 位作者 LU Xuan-dong HE Xu-hui CAI Chen-zhi 《Journal of Central South University》 SCIE EI CAS CSCD 2025年第11期4439-4462,共24页
Structural damage detection is hard to conduct in large-scale civil structures due to enormous structural data and insufficient damage features.To improve this situation,a damage detection method based on model reduct... Structural damage detection is hard to conduct in large-scale civil structures due to enormous structural data and insufficient damage features.To improve this situation,a damage detection method based on model reduction and response reconstruction is presented.Based on the framework of two-step model updating including substructure-level localization and element-level detection,the response reconstruction strategy with an improved sensitivity algorithm is presented to conveniently complement modal information and promote the reliability of model updating.In the iteration process,the reconstructed response is involved in the sensitivity algorithm as a reconstruction-related item.Besides,model reduction is applied to reduce computational degrees of freedom(DOFs)in each detection step.A numerical truss bridge is modelled to vindicate the effectiveness and efficiency of the method.The results showed that the presented method reduces the requirement for installed sensors while improving efficiency and ensuring accuracy of damage detection compared to traditional methods. 展开更多
关键词 damage detection model reduction response reconstruction two-step model updating sensitivity algorithm
暂未订购 下载PDF
Geometrically Nonlinear Deformation Reconstruction Based on iQS4 Elements Using a Linearized Iterative iFEM Algorithm 认领 引用 被引量:4
9
作者 Mengying Li Dawei Jia +2 位作者 He Huang Ziyan Wu Adnan Kefal 《Acta Mechanica Solida Sinica》 SCIE EI CSCD 2023年第1期166-180,共15页
Structural shape monitoring plays a vital role in the structural health monitoring systems.The inverse finite element method(iFEM)has been demonstrated to be a practical method of deformation reconstruction owing to i... Structural shape monitoring plays a vital role in the structural health monitoring systems.The inverse finite element method(iFEM)has been demonstrated to be a practical method of deformation reconstruction owing to its unique advantages.Current iFEM formulations have been applied to small deformation of structures based on the small-displacement assumption of linear theory.However,this assumption may be inapplicable to some structures with large displacements in practical applications.Therefore,geometric nonlinearity needs to be considered.In this study,to expand the practical utility of iFEM for large displacement monitoring,we propose a nonlinear iFEM algorithm based on a four-node inverse quadrilateral shell element iQS4.Taking the advantage of an iterative iFEM algorithm,a nonlinear response is linearized to compute the geometrically nonlinear deformation reconstruction,like the basic concept of nonlinear FE analysis.Several examples are solved to verify the proposed approach.It is demonstrated that large displacements can be accurately estimated even if the in-situ sensor data includes different levels of randomly generated noise.It is proven that the nonlinear iFEM algorithm provides a more accurate displacement response as compared to the linear iFEM methodology for structures undergoing large displacement.Hence,the proposed approach can be utilized as a viable tool to effectively characterize geometrically nonlinear deformations of structures in real-time applications. 展开更多
关键词 Deformation reconstruction iQS4 element Iterative algorithm Nonlinear iFEM Geometric nonlinearity
暂未订购 下载PDF
Research on the Application of Super Resolution Reconstruction Algorithm for Underwater Image 认领 引用 被引量:4
10
作者 Tingting Yang Shuwen Jia Hao Ma 《Computers, Materials & Continua》 SCIE EI 2020年第3期1249-1258,共10页
Underwater imaging is widely used in ocean,river and lake exploration,but it is affected by properties of water and the optics.In order to solve the lower-resolution underwater image formed by the influence of water a... Underwater imaging is widely used in ocean,river and lake exploration,but it is affected by properties of water and the optics.In order to solve the lower-resolution underwater image formed by the influence of water and light,the image super-resolution reconstruction technique is applied to the underwater image processing.This paper addresses the problem of generating super-resolution underwater images by convolutional neural network framework technology.We research the degradation model of underwater images,and analyze the lower-resolution factors of underwater images in different situations,and compare different traditional super-resolution image reconstruction algorithms.We further show that the algorithm of super-resolution using deep convolution networks(SRCNN)which applied to super-resolution underwater images achieves good results. 展开更多
关键词 Underwater image image super-resolution algorithm algorithm reconstruction degradation model
暂未订购 下载PDF
Sparse reconstruction for fluorescence molecular tomography via a fast iterative algorithm 认领 引用 被引量:4
11
作者 Jingjing Yu Jingxing Cheng +1 位作者 Yuqing Hou Xiaowei He 《Journal of Innovative Optical Health Sciences》 SCIE EI 2014年第3期50-58,共9页
Fluorescence molecular tomography(FMT)is a fast-developing optical imaging modalitythat has great potential in early diagnosis of disease and drugs development.However,recon-struction algorithms have to address a high... Fluorescence molecular tomography(FMT)is a fast-developing optical imaging modalitythat has great potential in early diagnosis of disease and drugs development.However,recon-struction algorithms have to address a highly ill-posed problem to fulfll 3D reconstruction inFMT.In this contribution,we propose an efficient iterative algorithm to solve the large-scalereconstruction problem,in which the sparsity of fluorescent targets is taken as useful a prioriinformation in designing the reconstruction algorithm.In the implementation,a fast sparseapproximation scheme combined with a stage-wise learning strategy enable the algorithm to dealwith the ill-posed inverse problem at reduced computational costs.We validate the proposed fastiterative method with numerical simulation on a digital mouse model.Experimental results demonstrate that our method is robust for different finite element meshes and different Poissonnoise levels. 展开更多
关键词 Fluorescence molecular tomography sparse regularization reconstruction algorithm least absolute shrinkage and selection operator.
暂未订购 下载PDF
Dose reconstruction with Compton camera during proton therapy via subset-driven origin ensemble and double evolutionary algorithm 认领 引用 被引量:4
12
作者 Zhi-Yang Yao Yong-Shun Xiao Ji-Zhong Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第4期135-148,共14页
Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstru... Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy. 展开更多
关键词 Prompt gamma imaging Dose reconstruction Range verification Origin ensemble Compton camera Evolutionary algorithm
暂未订购 下载PDF
Fast parallel algorithm for three-dimensional distance-driven model in iterative computed tomography reconstruction 认领 引用 被引量:1
13
作者 陈建林 李磊 +5 位作者 王林元 蔡爱龙 席晓琦 张瀚铭 李建新 闫镔 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第2期513-520,共8页
The projection matrix model is used to describe the physical relationship between reconstructed object and projection.Such a model has a strong influence on projection and backprojection,two vital operations in iterat... The projection matrix model is used to describe the physical relationship between reconstructed object and projection.Such a model has a strong influence on projection and backprojection,two vital operations in iterative computed tomographic reconstruction.The distance-driven model(DDM) is a state-of-the-art technology that simulates forward and back projections.This model has a low computational complexity and a relatively high spatial resolution;however,it includes only a few methods in a parallel operation with a matched model scheme.This study introduces a fast and parallelizable algorithm to improve the traditional DDM for computing the parallel projection and backprojection operations.Our proposed model has been implemented on a GPU(graphic processing unit) platform and has achieved satisfactory computational efficiency with no approximation.The runtime for the projection and backprojection operations with our model is approximately 4.5 s and 10.5 s per loop,respectively,with an image size of 256×256×256 and 360 projections with a size of 512×512.We compare several general algorithms that have been proposed for maximizing GPU efficiency by using the unmatched projection/backprojection models in a parallel computation.The imaging resolution is not sacrificed and remains accurate during computed tomographic reconstruction. 展开更多
关键词 computed tomography iterative reconstruction parallelizable algorithm distance-driven model
暂未订购 下载PDF
Improvement of Binocular Reconstruction Algorithm for Measuring 3D Pavement Texture Using a Single Laser Line Scanning Constraint 认领 引用 被引量:2
14
作者 Yuanyuan Wang RuiWang +1 位作者 Xiaofeng Ren Junan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1951-1972,共22页
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was... The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation. 展开更多
关键词 3D pavement texture binocular reconstruction algorithm single laser line scanning constraint improved stereo matching
暂未订购 下载PDF
Randomized Kaczmarz algorithm for CT reconstruction 认领 引用 被引量:1
15
作者 赵可 潘晋孝 孔慧华 《Journal of Measurement Science and Instrumentation》 CAS 2013年第1期34-37,共4页
The order of the projection in the algebraic reconstruction technique(ART)method has great influence on the rate of the convergence.Although many scholars have studied the order of the projection,few theoretical proof... The order of the projection in the algebraic reconstruction technique(ART)method has great influence on the rate of the convergence.Although many scholars have studied the order of the projection,few theoretical proofs are given.Thomas Strohmer and Roman Vershynin introduced a randomized version of the Kaczmarz method for consistent,and over-determined linear systems and proved whose rate does not depend on the number of equations in the systems in 2009.In this paper,we apply this method to computed tomography(CT)image reconstruction and compared images generated by the sequential Kaczmarz method and the randomized Kaczmarz method.Experiments demonstrates the feasibility of the randomized Kaczmarz algorithm in CT image reconstruction and its exponential curve convergence. 展开更多
关键词 Kaczmarz method iterative algorithm randomized Kaczmarz method computed tomography(CT) CT image reconstruction exponent curve fitting
暂未订购 下载PDF
Reconstruction of the linac photon spectrum based on prior knowledge and the genetic algorithm 认领 引用 被引量:1
16
作者 周正东 陈元华 +1 位作者 王东东 余子丽 《Journal of Southeast University(English Edition)》 EI CAS 2014年第3期311-314,共4页
In order to derive the linac photon spectrum accurately both the prior constrained model and the genetic algorithm GA are employed using the measured percentage depth dose PDD data and the Monte Carlo simulated monoen... In order to derive the linac photon spectrum accurately both the prior constrained model and the genetic algorithm GA are employed using the measured percentage depth dose PDD data and the Monte Carlo simulated monoenergetic PDDs where two steps are involved.First the spectrum is modeled as a prior analytical function with two parameters αand Ep optimized with the GA.Secondly the linac photon spectrum is modeled as a discretization constrained model optimized with the GA. The solved analytical function in the first step is used to generate initial solutions for the GA’s first run in this step.The method is applied to the Varian iX linear accelerator to derive the energy spectra of its 6 and 15 MV photon beams.The experimental results show that both the reconstructed spectrums and the derived PDDs with the proposed method are in good agreement with those calculated using the Monte Carlo simulation. 展开更多
关键词 reconstruction of the photon spectrum priorknowledge genetic algorithm (GA) percent depth dose(PDD) Monte Carlo simulation
暂未订购 下载PDF
Genetic Algorithm Based Tikhonov Regularization Method for Displacement Reconstruction 认领 引用 被引量:1
17
作者 PENG Zhen YANG Zhilong TU Jiahuang 《Journal of Shanghai Jiaotong university(Science)》 EI 2019年第3期294-298,共5页
In this paper,a genetic algorithm based Tikhonov regularization method is proposed for determination of globally optimal regularization factor in displacement reconstruction.Optimization mathematic models are built by... In this paper,a genetic algorithm based Tikhonov regularization method is proposed for determination of globally optimal regularization factor in displacement reconstruction.Optimization mathematic models are built by using the generalized cross-validation(GCV)criterion,L-curve criterion and Engl’s error minimization(EEM)criterion as the objective functions to prevent the regularization factor sinking into the locally optimal solution.The validity of the proposed algorithm is demonstrated through a numerical study of the frame structure model.Additionally,the influence of the noise level and the number of sampling points on the optimal regularization factor is analyzed.The results show that the proposed algorithm improves the robustness of the algorithm effectively,and reconstructs the displacement accurately. 展开更多
关键词 genetic algorithm Tikhonov regularization displacement reconstruction inverse problem parameter optimization
暂未订购 下载PDF
Research on the Signal Reconstruction of the Phased Array Structural Health Monitoring Based Using the Basis Pursuit Algorithm 认领 引用 被引量:3
18
作者 Yajie Sun Yanqing Yuan +3 位作者 Qi Wang Lihua Wang Enlu Li Li Qiao 《Computers, Materials & Continua》 SCIE EI 2019年第2期409-420,共12页
The signal processing problem has become increasingly complex and demand high acquisition system,this paper proposes a new method to reconstruct the structure phased array structural health monitoring signal.The metho... The signal processing problem has become increasingly complex and demand high acquisition system,this paper proposes a new method to reconstruct the structure phased array structural health monitoring signal.The method is derived from the compressive sensing theory and the signal is reconstructed by using the basis pursuit algorithm to process the ultrasonic phased array signals.According to the principles of the compressive sensing and signal processing method,non-sparse ultrasonic signals are converted to sparse signals by using sparse transform.The sparse coefficients are obtained by sparse decomposition of the original signal,and then the observation matrix is constructed according to the corresponding sparse coefficients.Finally,the original signal is reconstructed by using basis pursuit algorithm,and error analysis is carried on.Experimental research analysis shows that the signal reconstruction method can reduce the signal complexity and required the space efficiently. 展开更多
关键词 Basis pursuit algorithm compressive sensing phased array signal reconstruction
暂未订购 下载PDF
An Iterative Algorithm for Computed Tomography Image Reconstruction from Limited-Angle Projections 认领 引用 被引量:1
19
作者 孙玉立 陶进绪 +1 位作者 陈浩 刘从桂 《Journal of Shanghai Jiaotong university(Science)》 EI 2015年第2期202-208,共7页
In application of tomography imaging, limited-angle problem is a quite practical and important issue.In this paper, an iterative reprojection-reconstruction(IRR) algorithm using a modified Papoulis-Gerchberg(PG)iterat... In application of tomography imaging, limited-angle problem is a quite practical and important issue.In this paper, an iterative reprojection-reconstruction(IRR) algorithm using a modified Papoulis-Gerchberg(PG)iterative scheme is developed for reconstruction from limited-angle projections which contain noise. The proposed algorithm has two iterative update processes, one is the extrapolation of unknown data, and the other is the modification of the known noisy observation data. And the algorithm introduces scaling factors to control the two processes, respectively. The convergence of the algorithm is guaranteed, and the method of choosing the scaling factors is given with energy constraints. The simulation result demonstrates our conclusions and indicates that the algorithm proposed in this paper can obviously improve the reconstruction quality. 展开更多
关键词 computed tomography limited-angle reconstruction Papoulis-Gerchberg algorithm
暂未订购 下载PDF
Preliminary clinical application of an adaptive iterative statistical reconstruction algorithm inhead and neck computed tomography angiography with low tube voltage and a low concentration of contrast medium 认领 引用 被引量:2
20
作者 Shan Hu Wenzhen Zhu +4 位作者 Daoyu Hu XiaoYan Meng Jinhua Zhang Weijia Wan Li Zhou 《Oncology and Translational Medicine》 CAS 2015年第4期171-176,共6页
Objective To evaluate the feasibility of using a low concentration of contrast medium (Visipaque 270 mgl/mL), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography ang... Objective To evaluate the feasibility of using a low concentration of contrast medium (Visipaque 270 mgl/mL), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography angiography (CTA). Methods Forty patients (22 men and 18 women; average age 48.7 ± 14.25 years; average body mass index 23.9 ± 3.7 kg/m^2) undergoing CTA for suspected vascular diseases were randomly assigned into two groups. Group A (n = 20) was administered 370 mgl/mL contrast medium, and group B (n = 20) was administered 270 mgl/mL contrast medium. Both groups were administered at a rate of 4.8 mL/s and an injection volume of 0.8 mL/kg. Images of group A were obtained with 120 kVp and filtered back projection (FBP) reconstruction, whereas images of group B were obtained with 80 kVp and 80% adaptive iterative statistical reconstruction algorithm (ASiR). The CT values and standard deviations of intracranial arteries and image noise on the corona radiata were measured to calculate the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). The beam-hardening artifacts (BHAs) around the skull base were calculated. Two readers evaluated the image quality with volume rendered images using scores from 1 to 5. The values between the two groups were statistically compared. Results The mean CT value of the intracranial arteries in group B was significantly higher than that in group A (P 〈 0.001). The CNR and SNR values in group B were also statistically higher than those in group A (P 〈 0.001). Image noise and BHAs were not significantly different between the two groups. The image quality score of VR images of in group B was significantly higher than that in group A (P = 0.001). However, the quality scores of axial enhancement images in group B became significantly smaller than those in group A (P〈 0.001). The CT dose index volume and dose-length product were decreased by 63.8% and 64%, respectively, in group B (P 〈 0.001 for both). Conclusion Visipaque combined with 80 kVp and 80% ASiR provided similar image quality in intracranial CTA with 64% radiation dose reduction compared with the use of lopamidol, 120 kVp, and FBP reconstruc-tion. 展开更多
关键词 low concentration contrast medium head and neck computed tomography angiography adaptive iterative statistical reconstruction algorithm
暂未订购 下载PDF
上一页 1 2 137 下一页 到第
在线咨询 使用帮助 返回顶部 意见反馈