The pulse shape discrimination technique plays a pivotal role in neutron field measurements using organic scintillator detectors,and the particle-type labeling accuracy of the pulse waveform dataset has a significant ...The pulse shape discrimination technique plays a pivotal role in neutron field measurements using organic scintillator detectors,and the particle-type labeling accuracy of the pulse waveform dataset has a significant impact on its performance,especially with the growing use of machine learning methods.In this study,a high-accuracy labeling method for pulse waveform datasets based on the time-of-flight(TOF)filtering method,an improved charge comparison method(CCM),and the coincidence measurement method is proposed.The relationship between the experimental parameters and the chance coincidence proportion in the TOF measurement was derived to reduce contamination from chance coincidences at the experimental level.Based on this,an experiment was conducted to obtain raw data using the241AmBe source,and a piled-up identification algorithm based on reference waveform cross-correlation and differential analysis was designed to filter out piled-up pulses.To improve the labeling accuracy,the CCM was optimized,a simple method of selecting the TOF interval for a lower chance coincidence proportion was proposed,and a low-amplitude pulse waveform dataset construction method based on coincidence measurements was developed.To verify these methods,eight pulse waveform datasets were constructed using different combinations of the proposed approaches.Three neural network structures and a corresponding evaluation parameter were designed to test the quality of these datasets.The results showed that the particle identification performance of the CCM was significantly improved after optimization,with the neutron-to-gamma-ray misidentification rate reduced by more than 35%.The proposed accuracy improvement methods reduced ambiguous identification results from these artificial neural networks by more than 50%.展开更多
There are a lot of methods in city water consumption short-term forecasting both inside and outside the country. But among these methods there exist many advantages and shortcomings in model establishing, solving and ...There are a lot of methods in city water consumption short-term forecasting both inside and outside the country. But among these methods there exist many advantages and shortcomings in model establishing, solving and predicting accuracy, speed, applicability. This article draws lessons from other realm mature methods after many years′ study. It′s systematically studied and compared to predict the water consumption in accuracy, speed, effect and applicability among the time series triangle function method, artificial neural network method, gray system theories method, wavelet analytical method.展开更多
Microsatellite markers have become one kind of the most important molecular tools used in various researches. A large number of microsatellite markers are required for the whole genome survey in the fields of molecula...Microsatellite markers have become one kind of the most important molecular tools used in various researches. A large number of microsatellite markers are required for the whole genome survey in the fields of molecular ecology,quantitative genetics and genomics. Therefore,it is extremely necessary to select several versatile,low-cost,efficient and time-and labor-saving methods to develop a large panel of microsatellite markers. In this study,we used Zhikong scallop(Chlamys farreri) as the target species to compare the efficiency of the five methods derived from three strategies for microsatellite marker development. The results showed that the strategy of constructing small insert genomic DNA library resulted in poor efficiency,while the microsatellite-enriched strategy highly improved the isolation efficiency. Although the mining public database strategy is time-and cost-saving,it is difficult to obtain a large number of microsatellite markers,mainly due to the limited sequence data of non-model species deposited in public databases. Based on the results in this study,we recommend two methods,microsatellite-enriched library construction method and FIASCO-colony hybridization method,for large-scale microsatellite marker development. Both methods were derived from the microsatellite-enriched strategy. The experimental results obtained from Zhikong scallop also provide the reference for microsatellite marker development in other species with large genomes.展开更多
Twenty-one typical coupled large samples were chosen from areas within and surrounding nature reserves on the Tibetan Plateau using the large sample comparison method(LSCM).To evaluate the effectiveness of the nature ...Twenty-one typical coupled large samples were chosen from areas within and surrounding nature reserves on the Tibetan Plateau using the large sample comparison method(LSCM).To evaluate the effectiveness of the nature reserves in protecting the ecological environment,the alpine grassland net primary production(NPP) of these coupled samples were compared and the differences between them before and after their establishment as protected areas were analyzed.The results showed that:(1) With respect to the alpine grassland NPP,the ecological and environmental conditions of most nature reserves were more fragile than those of the surrounding areas and also lower than the average values for the Tibetan Plateau.(2) Of the 11 typical nature reserves selected,the positive trend in the NPP for Manzetang was the most significant,whereas there was no obvious trend in Taxkorgan.With the exception of Selincuo,the annual NPP growth rate in the nature reserves covered by alpine meadow and wetland was higher than that in nature reserves consisting of alpine steppe and alpine desert.(3) There were notable findings in 21 typical coupled samples:(a) After the establishment of the nature reserves,the annual rate of increase in the NPP in 76% of samples inside nature reserves and 82% of samples inside national nature reserves was higher than that of the corresponding samples outside nature reserves.(b) The effectiveness of ecological protection of the Mid-Kunlun,Changshagongma,Zoige and Selincuo(Selin Co) nature reserves was significant; the effectiveness of protection was relatively sig-nificant in most parts of the Sanjiangyuan and Qiangtang nature reserves,whereas in south-east Manzetang and north Taxkorgan the protection effectiveness was not obvious.(c) The ecological protection effectiveness was significant in nature reserves consisting of alpine meadow,but was weak in nature reserves covered by alpine steppe.This study also shows that the advantage of large sample comparison method in evaluating regional ecology change.Careful design of the samples used,to ensure comparability between the samples,is crucial to the success of this LSCM.展开更多
We compare three different methods to extract coherent modes from Doppler backscattering (DBS), which are center of gravity (COG) of the complex amplitude spectrum, spectrum of DBS phase derivative (phase derivat...We compare three different methods to extract coherent modes from Doppler backscattering (DBS), which are center of gravity (COG) of the complex amplitude spectrum, spectrum of DBS phase derivative (phase derivative method), and phase spectrum, respectively. These three methods are all feasible to extract coherent modes, for example, geodesic acoustic mode oscillation. However, there are stilI differences between dealing with high frequency modes (several hundred kHz) and low frequency modes, (several kHz) hiding in DBS signal. There is a significant amount of power at low frequencies in the phase spectrum, which can be removed by using the phase derivative method and COG. High frequency modes are clearer by using the COO and the phase derivative method than the phase spectrum. The spectrum of DBS amplitude does not show the coherent modes detected by using COG, phase derivative method and phase spectrum. When two Doppler shifted peaks exist, coherent modes and their harmonics appear in the spectrum of DBS amplitude, which are introduced by the DBS phase.展开更多
Objectives: Dengue virus (DENV) infection is a mosquito-borne disease that stands out as one of the major public health issues and has a wide-ranging geographical distribution throughout the tropics and subtropics. Th...Objectives: Dengue virus (DENV) infection is a mosquito-borne disease that stands out as one of the major public health issues and has a wide-ranging geographical distribution throughout the tropics and subtropics. The general alarming increase in the number of cases over the last two decades can be attributed to an extent by the change in national practices to keeping records and reporting dengue to the Ministries of Health, and WHO. Dengue diagnosis is routinely carried out by detection of dengue virus (DENV) antigen NS1 (Non-structural Antigen 1) and/or anti-DENV IgM/IgG antibodies using enzyme-linked immunosorbent assays (ELISAs) and rapid diagnostic tests (RDTs). This study compared the performance of three RDTs and one ELISA used for dengue diagnosis in southeastern, Nigeria. Design: This study adopted a cross-sectional design that included prospective hospital-based surveillance of cases among febrile participants attending two major health facilities within the southeastern region of Nigeria. In this study, 338 HIV-infected participants from two teaching hospitals in Nigeria’s southeast were systematically tested for Dengue with four methods: NS1 RDT, IgG RDT, IgM RDT, and NS1 ELISA. Their specificities and sensitivities were compared, as well as their level of concordance. Their respective performances were also evaluated using the Receivers Operational curve (ROC). Results: Out of the 338 patients, the dengue prevalence from the four dengue diagnostic methods Dengue virus NS1 ELISA, NS1 RDT, IgM and IgG seropositivity were 8.9%, 0.6%, 5.6%, and 8.0%, respectively. The Dengue IgM RDT test indicated 36.8% sensitivity, 92.8% specificity, the IgG anti-dengue specific test indicated 29.6% sensitivity, 92.9% specificity and the dengue NS1 RDT test indicated 3.3% sensitivity, 99.4% specificity when compared with the Dengue NSI Elisa test method as a reference method. Conclusion: The use of NSI ELISA for DENV diagnosis showed good performance and the RDTs showed, to an extent, reliable results compared with ELISA. However, diagnostic laboratories should be aware of performance variations across tests and the possibilities of cross-reactivity that may affect results.展开更多
Polyphenols,teroens,and resinsmake it difficult to obtain high qualitygenomic DNA from rice.Four ex-traction methods were compared inour study,and CTAB precipitationwas the most practical one.Materials used were old l...Polyphenols,teroens,and resinsmake it difficult to obtain high qualitygenomic DNA from rice.Four ex-traction methods were compared inour study,and CTAB precipitationwas the most practical one.Materials used were old leavesfrom Ftransgenic rice in Hainan andfresh leaves from Ftransgenic rice inKunming.Procedures of the four methodswere as follows:1.Basical method:powder 1 gold or new leaves→added 2 ml ex-traction solution(100 mmol/L展开更多
AIMTo describe the development and validation of a novel neuronavigation-based method, which allows the quan-tification of the anatomical features that define anapproach, as well as real-time visualization of the surg...AIMTo describe the development and validation of a novel neuronavigation-based method, which allows the quan-tification of the anatomical features that define anapproach, as well as real-time visualization of the surgicapyramid. METHODSThe method was initially developed with commercially-available hardware for coordinate collection (a digitizerand a frameless navigation system) and software forvolume rendering; dedicated neuronavigation software (ApproachViewer, part of GTx-UHN) was then developed. The accuracy of measurements and the possibility of volumetric rendering of surgical approaches simulated in a phantom were compared among three different methods and commercially-available radiological software. In the anatomy laboratory, ApproachViewer was applied to the comparative quantitative analysis of multiple neurosurgical approaches and was used by many surgeons who were untrained for the research method.RESULTSThe accuracy of ApproachViewer is comparable to com-mercially-available radiological software. In the anatomy laboratory, the method appears versatile. The system can be easily used after brief training. ApproachViewer allows for real-time evaluation and comparison of surgical approaches, as well as post-dissection analyses of collected data. The accuracy of the method depends on the navigation registration: with a 1-2 mm registration error, it is adequate for evaluation and comparison of most neurosurgical approaches.CONCLUSIONThis new research method and software allows semi-automated visualization, quantifcation, and comparison of neurosurgical approaches in the anatomy laboratory.展开更多
Gas chromatography equipped with an electron capture detector (GC-ECD) has been widely used for measuring atmospheric N2O,but nonlinear response and the influence of atmospheric CO2 have been recognized as defects f...Gas chromatography equipped with an electron capture detector (GC-ECD) has been widely used for measuring atmospheric N2O,but nonlinear response and the influence of atmospheric CO2 have been recognized as defects for quantification.An original GCECD method using N 2 as carrier gas was improved by introducing a small flow rate of CO2 makeup gas into the ECD,which could well remedy the above defects.The N2O signal of the improved method was 4-fold higher than that of the original method and the relative standard deviation was reduced from 〉 1% to 0.31%.N2O concentrations with different CO2 concentrations (172.2×10-6-1722×10-6mol/mol) measured by the improved GC-ECD method were in line with the actual N2O concentrations.However,the N2O concentrations detected by the original method were largely biased with a variation range of-4.5%~7%.The N2O fluxes between an agricultural field and the atmosphere measured by the original method were greatly overestimated in comparison with those measured by the improved method.Good linear correlation (R2=0.9996) between the response of the improved ECD and N2O concentrations (93×10-9-1966×10-9mol/mol) indicated that atmospheric N2O could be accurately quantified via a single standard gas.Atmospheric N2O concentrations comparatively measured by the improved method and a high precision GC-ECD method were in good agreement.展开更多
目的验证5种小而密低密度脂蛋白胆固醇(sdLDL‑C)试剂的分析性能及检测结果一致性,为临床实验室方法学选择和标准化提供参考。方法在Beckman AU 5800全自动生化分析仪上对国内已获国家药品监督管理局医疗器械注册证的5种sdLDL‑C试剂(标为...目的验证5种小而密低密度脂蛋白胆固醇(sdLDL‑C)试剂的分析性能及检测结果一致性,为临床实验室方法学选择和标准化提供参考。方法在Beckman AU 5800全自动生化分析仪上对国内已获国家药品监督管理局医疗器械注册证的5种sdLDL‑C试剂(标为A、B、C、D、E)进行验证。参考国家卫生行业标准及美国临床和实验室标准协会文件的要求分别对5种sdLDL‑C试剂进行精密度、线性、参考区间验证及方法学比对。精密度采用高低浓度混合血清及第三方质控物。线性范围经梯度混合血清样本验证。从北京协和医院体检人群临床检测剩余样本中选取70例表观健康人,对参考区间进行验证。选取2022年11月至2023年1月临床检测剩余血清246例,用于5种试剂比对。结果5种sdLDL‑C试剂的重复性为1.1%~5.5%,实验室内不精密度为3.2%~7.0%。除试剂C外,其余4种试剂在说明书声称的分析测量范围内均呈线性(r≥0.990),且检测值与理论值的偏差均在15%以内。A~E各试剂结果落在各自提供参考区间的比例依次为100%(70/70)、94.3%(66/70)、92.9%(65/70)、98.6%(69/70)、80.0%(56/70)。5种试剂与其测定均值的相关系数r分别在0.933~0.981之间,平均绝对百分偏倚在8.3%~32.3%之间,与均值比较的平均偏倚在‑0.12~0.21 mmol/L之间。结论应用于自动生化分析仪的5种sdLDL‑C酶法试剂,具有较高的精密度,但一致性仍需提高。展开更多
基金supported by the National Natural Science Foundation of China(Nos.12375297 and 12105144).
摘要The pulse shape discrimination technique plays a pivotal role in neutron field measurements using organic scintillator detectors,and the particle-type labeling accuracy of the pulse waveform dataset has a significant impact on its performance,especially with the growing use of machine learning methods.In this study,a high-accuracy labeling method for pulse waveform datasets based on the time-of-flight(TOF)filtering method,an improved charge comparison method(CCM),and the coincidence measurement method is proposed.The relationship between the experimental parameters and the chance coincidence proportion in the TOF measurement was derived to reduce contamination from chance coincidences at the experimental level.Based on this,an experiment was conducted to obtain raw data using the241AmBe source,and a piled-up identification algorithm based on reference waveform cross-correlation and differential analysis was designed to filter out piled-up pulses.To improve the labeling accuracy,the CCM was optimized,a simple method of selecting the TOF interval for a lower chance coincidence proportion was proposed,and a low-amplitude pulse waveform dataset construction method based on coincidence measurements was developed.To verify these methods,eight pulse waveform datasets were constructed using different combinations of the proposed approaches.Three neural network structures and a corresponding evaluation parameter were designed to test the quality of these datasets.The results showed that the particle identification performance of the CCM was significantly improved after optimization,with the neutron-to-gamma-ray misidentification rate reduced by more than 35%.The proposed accuracy improvement methods reduced ambiguous identification results from these artificial neural networks by more than 50%.
摘要There are a lot of methods in city water consumption short-term forecasting both inside and outside the country. But among these methods there exist many advantages and shortcomings in model establishing, solving and predicting accuracy, speed, applicability. This article draws lessons from other realm mature methods after many years′ study. It′s systematically studied and compared to predict the water consumption in accuracy, speed, effect and applicability among the time series triangle function method, artificial neural network method, gray system theories method, wavelet analytical method.
基金supported by ‘863’ Program (2006AA10A408 and 2006AA10A411), NSFC30571417, NYHYZX07-047, 2005DKA30470, 2006BAD09A10 and NCET-06-0594.
摘要Microsatellite markers have become one kind of the most important molecular tools used in various researches. A large number of microsatellite markers are required for the whole genome survey in the fields of molecular ecology,quantitative genetics and genomics. Therefore,it is extremely necessary to select several versatile,low-cost,efficient and time-and labor-saving methods to develop a large panel of microsatellite markers. In this study,we used Zhikong scallop(Chlamys farreri) as the target species to compare the efficiency of the five methods derived from three strategies for microsatellite marker development. The results showed that the strategy of constructing small insert genomic DNA library resulted in poor efficiency,while the microsatellite-enriched strategy highly improved the isolation efficiency. Although the mining public database strategy is time-and cost-saving,it is difficult to obtain a large number of microsatellite markers,mainly due to the limited sequence data of non-model species deposited in public databases. Based on the results in this study,we recommend two methods,microsatellite-enriched library construction method and FIASCO-colony hybridization method,for large-scale microsatellite marker development. Both methods were derived from the microsatellite-enriched strategy. The experimental results obtained from Zhikong scallop also provide the reference for microsatellite marker development in other species with large genomes.
基金The Strategic Priority Research Program of the Chinese Academy of Sciences,No.XDB03030500National Key Technology Research and Development Program,No.2013BAC04B02+1 种基金Key Foundation Project of Basic Work of the Ministry of Science and Technology of China,No.2012FY111400National Natural Science Foundation of China,No.41171080,No.41201095
摘要Twenty-one typical coupled large samples were chosen from areas within and surrounding nature reserves on the Tibetan Plateau using the large sample comparison method(LSCM).To evaluate the effectiveness of the nature reserves in protecting the ecological environment,the alpine grassland net primary production(NPP) of these coupled samples were compared and the differences between them before and after their establishment as protected areas were analyzed.The results showed that:(1) With respect to the alpine grassland NPP,the ecological and environmental conditions of most nature reserves were more fragile than those of the surrounding areas and also lower than the average values for the Tibetan Plateau.(2) Of the 11 typical nature reserves selected,the positive trend in the NPP for Manzetang was the most significant,whereas there was no obvious trend in Taxkorgan.With the exception of Selincuo,the annual NPP growth rate in the nature reserves covered by alpine meadow and wetland was higher than that in nature reserves consisting of alpine steppe and alpine desert.(3) There were notable findings in 21 typical coupled samples:(a) After the establishment of the nature reserves,the annual rate of increase in the NPP in 76% of samples inside nature reserves and 82% of samples inside national nature reserves was higher than that of the corresponding samples outside nature reserves.(b) The effectiveness of ecological protection of the Mid-Kunlun,Changshagongma,Zoige and Selincuo(Selin Co) nature reserves was significant; the effectiveness of protection was relatively sig-nificant in most parts of the Sanjiangyuan and Qiangtang nature reserves,whereas in south-east Manzetang and north Taxkorgan the protection effectiveness was not obvious.(c) The ecological protection effectiveness was significant in nature reserves consisting of alpine meadow,but was weak in nature reserves covered by alpine steppe.This study also shows that the advantage of large sample comparison method in evaluating regional ecology change.Careful design of the samples used,to ensure comparability between the samples,is crucial to the success of this LSCM.
基金Supported by the National Natural Science Foundation of China under Grant Nos 10990210 and 11475173the National Magnetic Confinement Fusion Energy Program of China under Grant Nos 2013GB106002 and 2014GB109002
摘要We compare three different methods to extract coherent modes from Doppler backscattering (DBS), which are center of gravity (COG) of the complex amplitude spectrum, spectrum of DBS phase derivative (phase derivative method), and phase spectrum, respectively. These three methods are all feasible to extract coherent modes, for example, geodesic acoustic mode oscillation. However, there are stilI differences between dealing with high frequency modes (several hundred kHz) and low frequency modes, (several kHz) hiding in DBS signal. There is a significant amount of power at low frequencies in the phase spectrum, which can be removed by using the phase derivative method and COG. High frequency modes are clearer by using the COO and the phase derivative method than the phase spectrum. The spectrum of DBS amplitude does not show the coherent modes detected by using COG, phase derivative method and phase spectrum. When two Doppler shifted peaks exist, coherent modes and their harmonics appear in the spectrum of DBS amplitude, which are introduced by the DBS phase.
摘要Objectives: Dengue virus (DENV) infection is a mosquito-borne disease that stands out as one of the major public health issues and has a wide-ranging geographical distribution throughout the tropics and subtropics. The general alarming increase in the number of cases over the last two decades can be attributed to an extent by the change in national practices to keeping records and reporting dengue to the Ministries of Health, and WHO. Dengue diagnosis is routinely carried out by detection of dengue virus (DENV) antigen NS1 (Non-structural Antigen 1) and/or anti-DENV IgM/IgG antibodies using enzyme-linked immunosorbent assays (ELISAs) and rapid diagnostic tests (RDTs). This study compared the performance of three RDTs and one ELISA used for dengue diagnosis in southeastern, Nigeria. Design: This study adopted a cross-sectional design that included prospective hospital-based surveillance of cases among febrile participants attending two major health facilities within the southeastern region of Nigeria. In this study, 338 HIV-infected participants from two teaching hospitals in Nigeria’s southeast were systematically tested for Dengue with four methods: NS1 RDT, IgG RDT, IgM RDT, and NS1 ELISA. Their specificities and sensitivities were compared, as well as their level of concordance. Their respective performances were also evaluated using the Receivers Operational curve (ROC). Results: Out of the 338 patients, the dengue prevalence from the four dengue diagnostic methods Dengue virus NS1 ELISA, NS1 RDT, IgM and IgG seropositivity were 8.9%, 0.6%, 5.6%, and 8.0%, respectively. The Dengue IgM RDT test indicated 36.8% sensitivity, 92.8% specificity, the IgG anti-dengue specific test indicated 29.6% sensitivity, 92.9% specificity and the dengue NS1 RDT test indicated 3.3% sensitivity, 99.4% specificity when compared with the Dengue NSI Elisa test method as a reference method. Conclusion: The use of NSI ELISA for DENV diagnosis showed good performance and the RDTs showed, to an extent, reliable results compared with ELISA. However, diagnostic laboratories should be aware of performance variations across tests and the possibilities of cross-reactivity that may affect results.
摘要Polyphenols,teroens,and resinsmake it difficult to obtain high qualitygenomic DNA from rice.Four ex-traction methods were compared inour study,and CTAB precipitationwas the most practical one.Materials used were old leavesfrom Ftransgenic rice in Hainan andfresh leaves from Ftransgenic rice inKunming.Procedures of the four methodswere as follows:1.Basical method:powder 1 gold or new leaves→added 2 ml ex-traction solution(100 mmol/L
基金Supported by Fondazione"Giuseppe Alazio",via Torquato Tasso,22,90144 Palermo,Italy(to Doglietto F)
摘要AIMTo describe the development and validation of a novel neuronavigation-based method, which allows the quan-tification of the anatomical features that define anapproach, as well as real-time visualization of the surgicapyramid. METHODSThe method was initially developed with commercially-available hardware for coordinate collection (a digitizerand a frameless navigation system) and software forvolume rendering; dedicated neuronavigation software (ApproachViewer, part of GTx-UHN) was then developed. The accuracy of measurements and the possibility of volumetric rendering of surgical approaches simulated in a phantom were compared among three different methods and commercially-available radiological software. In the anatomy laboratory, ApproachViewer was applied to the comparative quantitative analysis of multiple neurosurgical approaches and was used by many surgeons who were untrained for the research method.RESULTSThe accuracy of ApproachViewer is comparable to com-mercially-available radiological software. In the anatomy laboratory, the method appears versatile. The system can be easily used after brief training. ApproachViewer allows for real-time evaluation and comparison of surgical approaches, as well as post-dissection analyses of collected data. The accuracy of the method depends on the navigation registration: with a 1-2 mm registration error, it is adequate for evaluation and comparison of most neurosurgical approaches.CONCLUSIONThis new research method and software allows semi-automated visualization, quantifcation, and comparison of neurosurgical approaches in the anatomy laboratory.
基金supported by the Special Fund for Environmental Research in the Public Interest(No.201009001)the National Natural Science Foundation of China(No.41075094,21177140 and 40830101)the National Basic Research and the Development Program(973)of China(No.2010CB732304)
摘要Gas chromatography equipped with an electron capture detector (GC-ECD) has been widely used for measuring atmospheric N2O,but nonlinear response and the influence of atmospheric CO2 have been recognized as defects for quantification.An original GCECD method using N 2 as carrier gas was improved by introducing a small flow rate of CO2 makeup gas into the ECD,which could well remedy the above defects.The N2O signal of the improved method was 4-fold higher than that of the original method and the relative standard deviation was reduced from 〉 1% to 0.31%.N2O concentrations with different CO2 concentrations (172.2×10-6-1722×10-6mol/mol) measured by the improved GC-ECD method were in line with the actual N2O concentrations.However,the N2O concentrations detected by the original method were largely biased with a variation range of-4.5%~7%.The N2O fluxes between an agricultural field and the atmosphere measured by the original method were greatly overestimated in comparison with those measured by the improved method.Good linear correlation (R2=0.9996) between the response of the improved ECD and N2O concentrations (93×10-9-1966×10-9mol/mol) indicated that atmospheric N2O could be accurately quantified via a single standard gas.Atmospheric N2O concentrations comparatively measured by the improved method and a high precision GC-ECD method were in good agreement.
摘要目的验证5种小而密低密度脂蛋白胆固醇(sdLDL‑C)试剂的分析性能及检测结果一致性,为临床实验室方法学选择和标准化提供参考。方法在Beckman AU 5800全自动生化分析仪上对国内已获国家药品监督管理局医疗器械注册证的5种sdLDL‑C试剂(标为A、B、C、D、E)进行验证。参考国家卫生行业标准及美国临床和实验室标准协会文件的要求分别对5种sdLDL‑C试剂进行精密度、线性、参考区间验证及方法学比对。精密度采用高低浓度混合血清及第三方质控物。线性范围经梯度混合血清样本验证。从北京协和医院体检人群临床检测剩余样本中选取70例表观健康人,对参考区间进行验证。选取2022年11月至2023年1月临床检测剩余血清246例,用于5种试剂比对。结果5种sdLDL‑C试剂的重复性为1.1%~5.5%,实验室内不精密度为3.2%~7.0%。除试剂C外,其余4种试剂在说明书声称的分析测量范围内均呈线性(r≥0.990),且检测值与理论值的偏差均在15%以内。A~E各试剂结果落在各自提供参考区间的比例依次为100%(70/70)、94.3%(66/70)、92.9%(65/70)、98.6%(69/70)、80.0%(56/70)。5种试剂与其测定均值的相关系数r分别在0.933~0.981之间,平均绝对百分偏倚在8.3%~32.3%之间,与均值比较的平均偏倚在‑0.12~0.21 mmol/L之间。结论应用于自动生化分析仪的5种sdLDL‑C酶法试剂,具有较高的精密度,但一致性仍需提高。