Pseudo-dynamic tests on masonry residential buildings seismically retrofitted by precast steel reinforced concrete walls 认领 引用 被引量:4
1
作者 Li Wenfeng Wang Tao +2 位作者 Chen Xi Zhong Xiang Pan Peng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第3期587-597,共11页
A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system s... A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests. 展开更多
关键词 masonry buildings precast SRC panel seismic retrofit pseudo-dynamic test seismic performance
暂未订购 下载PDF
上一页 1 下一页 到第
在线咨询 使用帮助 返回顶部 意见反馈